Table 2:

Amplitude and rectification at 0–5 min recording

GroupDistri-
bution
Amplitude
at −60 mV (pA)
t Test
(vs control)
p ValueAmplitude
at +40 mV (pA)
t Test
(vs control)
p ValueRIN
Controln.a.−50.4 ± 5.1n.a.n.a.11.7 ± 0.7n.a.n.a.0.37 ± 0.047
tA594 (100 µm)Normal−36.8 ± 3.6t(12) = −2.1920.0499.2 ± 1.1t(12) = 1.9280.0780.38 ± 0.037
uA488 (100 µm)Normal−39.4 ± 3.1t(12) = −1.8710.0869.8 ± 0.4t(12) = 2.3470.0370.38 ± 0.027
vA594 (10 µm)Normal−39.6 ± 3.8t(10) = −1.5860.1448.4 ± 0.7t(10) = 3.1880.010.33 ± 0.035
  • n.a., Not applicable.