ANOVA 1. Effects of inclination rotation and magnetic stimulation on post-stimulus alpha-power | |||
---|---|---|---|
Two-way repeated measures ANOVA (N = 29) Inclination rotation × magnetic stimulation | F | p | ηp 2 |
Main effect of inclination rotation (SWEEP vs FIXED) | 3.26 | 0.08 | 0.19 |
Main effect of magnetic stimulation (active vs sham) | 2.47 | 0.13 | 0.09 |
Inclination rotation × magnetic stimulation (interaction) | 5.67 | 0.02* | 0.17 |
ANOVA 1 shows a significant interaction of inclination rotation (SWEEP vs FIXED) and magnetic stimulation (active vs sham) in the inclination experiments. Based on post hoc testing, alpha-ERD was significantly greater in SWEEP trials in active mode, compared with all other conditions (p < 0.05). In this table, F is the F-ratio statistic, p the probability value, and ηp 2 the partial η2 value from the ANOVA.