Parameters of pyramidal cell, OLM interneuron, and fast-spiking interneuron dynamics
| Parameter | Value |
|---|---|
| O-cells | |
| Cm | 100 pF |
| gleak | 50 nS |
| Eleak | −70 mV |
| | 1100 nS |
| EK | −90 mV |
| | 5200 nS |
| ENa | 55 mV |
| | 50 nS |
| | 145 nS |
| Eh | −20 mV |
| I-cells | |
| Cm | 100 pF |
| gleak | 10 nS |
| Eleak | −67 mV |
| | 8000 nS |
| EK | −100 mV |
| | 10,000 nS |
| ENa | 50 mV |
| ED | |
| Cm | 100 pF |
| gleak | 1 nS |
| Eleak | −68 mV |
All the parameter values and expressions here described were taken from the study by Rotstein et al. (2005), considering a surface area of 1 × 10−4 cm2, except for the reversal potential of the leakage current of the OLM, which was set to have the resting potential of the OLM cells at −60 mV, as reported in the study by Leão et al. (2012).