Summary of default model MT parameters used in simulations
| Parameter | Description | Value |
|---|---|---|
| NMT | Number of MT units | 225 |
| Coordinates of visual field left | ||
| Coordinates of MT RF left | Arranged in a 15 × 15 grid spaced apart by 7.1° (8 pixels) | |
| σd | Maximum extent of random deviation in MT direction preference about the radial direction | 180° |
| σr | Effective RF radius | 6° (7 pixels) |
| σv | Sensitivity to optic flow that differs from the preferred direction | 10° |
| σs | Sensitivity to optic flow that differs from the preferred speed | 0.5°/s (0.45 pixels/s) |
| αMT | MT activation passive decay rate | 0.1 |
| βMT | MT activation upper bound | 2.5 |
| dt | Integration time step | 0.1 |